Wired terminals

Configuration

Zone parameters are set in the Zones tab of the configurator:

The zone type determines whether it will armed/disarmed when arming the partition and whether it will be accompanied by a siren and an indication in case of alarm. Always armed: Fire, Panic Button, Tamper sensor, 24-hour. No indication or siren in case of alarm activated in for: Security without siren and Panic button, Sensor Tamper.

In the“Partitions" tab, you need to add terminals to the required partitions and provide access to manage the partitions if necessary:

Connection

The signal cables of the loops are connected to terminals Z1-Z8:

General cables of the loops are connected to GND terminals.
Positive loop power cables (12 V) are connected to the PWR terminals. 

Activation scheme for signal cables:

For Nord GSM 5.2 / 5.3 / 5.4 / 5.5 / 5.7 / Nord Mini and Nord RF

Normally closed loop with two terminal resistors:
(Ranges, kOhm: SC <1.4 - Norm - 3.5 - Alarm - 6.6> Break)

Normally opened loop with two terminal resistors:
(Ranges, kOhm: SC <1.4 - Alarm - 2.8 - Norm - 6.6> Break)

Normally closed loop with one terminal resistor:
(Ranges, kOhm: SC <1.4 - Norm - 3.5 - Alarm)

Normally opened loop with one terminal resistor:
(Ranges, kOhm: Alarm < 2.8 - Norm - 6.6 > Alarm)

ForNord GSM 5.1

Normally closed loop with two terminal resistors:

Normally opened loop with two terminal resistors:

Normally closed loop with one terminal resistor:

Normally opened loop with one terminal resistor:

Additionally: