Nord GSM Air

Wireless control panel with built-in keypad for low-budget security systems. Suitable for small offices and flats.

Buy demo-kit

Nord Mini Air

Wireless control panel with built-in keypad for low-budget security systems. Suitable for small offices and flats.

Without wires

You can connect to Nord Mini Air up to 31 wireless devices: security sensors, smoke detectors, water leak sensors, temperature sensors, relay and repeaters.

List of devices

All included

Built-in keypad with backlit, remote 110/220 V power supply unit and battery 1.1 A*h, 3.7 V: not less than 12 hours of battery life.

Outputs, zones

Two discerete outputs for connection of wired siren or light alarm.

Two wired zones without power supply. You can connect wired magnetic contact and save you money.

Incredibly low cost of finished solution

At first, you don't need to buy power supply unit, battery and control devices — all included. Secondly, we produced budgetary sensors PIR-Mini and Magnetic-Mini specially for Nord Mini Air.

Wireless security system

Nord Mini Air
CN-PIR-Mini
CN-Magnetic-Mini
MyAlarm App

Quick installation of security system

Nord Mini Air has a compact body, so an engineer will easily find a place for mounting the device. Tracing paper with markings will allow for accurate drilling of fixing holes. The panel is wireless, so you do not need to pull wires and lay cable channels. It's simple and fast.

Slots for 2 sim-cards and terminals
Tracing paper for fixing holes
Backup power supply 1.1 A*h, 3.7 V
What is in the box with Nord Air

Easy configuration

The engineer connects the laptop to the Nord via USB
and configures device communication with console, partitions, users, sensors and other parameters of the alarm system. Engineer configures Nord with a special soft, we call it Hubble.

Hubble configurator

The feature of Hubble's work is that the engineer first creates a configuration device, and only then records to the device. Therefore, the configurator works quickly, reacting at lightning speed to engineer actions.

For typical sites, you can save configuration and record it on the device without wasting time on individual setting.

Interface for checking sensors and other devices

The configurator has an interface of devices' settings, it is called the status panel. Engineer sees number of zone, state and error signal level for each device.

The convenient web app for testing connection channels

Engineer tests both sim-cards: GPRS, CSD, voice channel and SMS.

App lets activate or desactivates any channel for testing.

Prize-winner at MIPS 2018

Nord GSM Air took the second place in The Best Innovative Product Awards.

Distant service

An engineer remotely connects to the Nord panel through the web interface of C.Nord Cloud and configures it with a Hubble configurator. The engineer configures the panel the same way as if he connects via USB.

Speed and safety

The panel configuration is stored on the device and in the cloud. Therefore, even if you have a bad connection with the device, Hubble will load up immediately (from the cloud) and the engineer starts to work at once.

The same is with the saving of settings. If connection is bad, the engineer does not have to wait: the new configuration immediately will be written into the cloud, and the cloud controls that this configuration will go to the device.

Safety

An engineer cannot connect to the control panel without permission. When it is necessary maintenance, an operator of the Security Center gives the engineer permission for remote access to a site for restricted time.

Rollout firmware update

We constantly refine our solutions: we produce new sensors, update the interface of the configurator, etc. For compatibility sometimes it is necessary to update the firmware of the control panel and other devices.

In the case of Nord panel, an engineer will not have to visit the site — he can updated the firmware remotely. Moreover, the engineer can update the firmware immediately on all or several devices and monitor the progress of the update.

Two ways to protect a site from hijacking by a competitor

1) You can switch off the reset configuration of control panel to the factory settings, and for access to configurator set a complex password.

If an engineer from a competing firm connected to the device via USB, he can't enter the configurator without the password.

2) You can connect the panel to your console. The address for connecting to the console is recorded in the internal memory of the processor and remains there even when the configuration is reset.

Help section about Nord Air

Contact us

Protection against inference panel fail

Even if the attackers break up panel, it will have time to send the event «Probable alarm» to the security console.

Installers put the control panel with a keypad at the entrance on the site, so that customers can conveniently enter the disarming code while there is a delay in the entrance.

We added the event "Probable alarm" (E138) to prevent inference panel fail during the "entry delay". It means, that if after a probable alarm from the site he disarming event will not come, then the console will form an alarm event.

Security Center

Nords are working with one of the best professional consoles in Russia — Security Center.

Security Center, Duty operator window.

MyAlarm App

Personal account for client of private security company and app to control security system and video surveillance.

Custom event timeline

You, as a security company, decide which events are on the custom event timeline in app: armings and disarmings, alarms of security sensors and alarms of utility sensors, operator actions during the alarm processing, reports of rapid-response groups.

Technological as a banking application

— Authorization by phone number and SMS-code;
— entrance by pin-code, Touch ID, and Face ID;
— push-notification of events;
— support ticket system;
— armings and disarmings , control of automation, video surveillance.

Temperature control

We output the readings of the temperature sensors on the screen of app.

Adjust the thresholds: then
with temperature changes above or below the threshold you will receive notifications.

Control automatics

You can open the gate,
switch on heating, light and much more directly from the app.

Utility sensors

You can connect smoke detectors and water leak sensors to the North GSM Air.

In case of triggering of sensors you will receive notifications until do not react.

Sound notifications

We voiced all the push-
notifications by Rita's voice. You definitely do not miss an important event among notifications on your phone.

Virtual panic button

The button is connected to the site, but you can press it from the app.

You can provide this service to your customers without installing an additional equipment.

Wireless devices for Nord Air

Technical specifications

Connection channels

GSM

2 sim-cards.
Internal GSM-antenna.
Remote GSM-antenna (option).

Wireless devices

31 devices

Security sensors, utility detectors: smoke, water and temperature; repeaters, extra keypad and relay.

Inputs and outputs

2 wired zones

Without power supply, modes: normal and alarm.

2 discrete outputs

With 2 wired zones (set in configurator).

1-Wire

You can connect TM or RFID-reader, light alarm, siren and remote temperature sensor.

Mini USB

Users and partitions

32 users

32 TM or RFID-keys

32 partitions

Housing

150x96x33 mm, plastic housing.

The housing includes: keypad, two LEDs, battery cover (front), access cover to sim-cards and a hole for access to the terminals (rear).

Power supply

Principal: remote power supply from the network 110/220 V (1 A, 12 V)

Backup: Battery 1.1 A*h, 3.7 V

At least 12 hours of battery life on the backup power source.

Temperature range

0…+50˚C

−20…+50˚C

When operating from an external backup power source. Not included in the standard kit.

Configuration

Mini USB (Hubble Configurator)

Virtual Expert App (Hubble configurator)

Bluetooth (soon)

Supply kit

The board of Nord Air in a plastic housing;

built-in keypad;

remote power supply unit from the 110/220 V network;

battery 1.1 A*h, 3.7 V;

built-in GSM-antenna.

Wiring diagram